{"title":"Magnetic Locks (Maglocks)","description":"\u003ch2 class=\"font-semibold pdf-heading-class-replace pb-1 text-2xl leading-[52px] [\u0026amp;:not(:first-child)]:pt-[30px] [\u0026amp;_.underline]:underline-offset-[6px] [\u0026amp;_a]:underline-offset-[6px]\"\u003e\u003cspan\u003eHeavy-Duty Magnetic Locks for Ultimate Building Security\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"text-md leading-[24px] font-regular pt-[9px] pb-0.5\"\u003e\u003cspan\u003eSecuring a busy commercial property or multi-tenant building demands hardware that never quits. \u003c\/span\u003e\u003cb\u003e\u003cstrong class=\"font-semibold\"\u003eMagnetic locks\u003c\/strong\u003e\u003c\/b\u003e\u003cspan\u003e, widely known as \u003c\/span\u003e\u003cb\u003e\u003cstrong class=\"font-semibold\"\u003emaglocks\u003c\/strong\u003e\u003c\/b\u003e\u003cspan\u003e, provide the raw holding power and mechanical reliability you need to protect your premises. Because they have no moving parts, they withstand heavy daily use without jamming or degrading.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"text-md leading-[24px] font-regular pt-[9px] pb-0.5\"\u003e\u003cspan\u003eWe supply a professional range of \u003c\/span\u003e\u003cb\u003e\u003cstrong class=\"font-semibold\"\u003emaglocks\u003c\/strong\u003e\u003c\/b\u003e\u003cspan\u003e designed specifically for locksmiths, trade installers, and commercial property managers. Door Entry Online delivers the exact trade-quality components we fit on our own installation sites, ensuring your security upgrades are built to last.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 class=\"font-semibold pdf-heading-class-replace pb-0.5 text-xl leading-[40px] [\u0026amp;:not(:first-child)]:pt-[21px] [\u0026amp;_.underline]:underline-offset-[6px] [\u0026amp;_a]:underline-offset-[6px]\"\u003e\u003cspan\u003eThe Core Benefits of Maglocks\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"text-md leading-[24px] font-regular pt-[9px] pb-0.5\"\u003e\u003cspan\u003eUpgrading your access control doors with \u003c\/span\u003e\u003cb\u003e\u003cstrong class=\"font-semibold\"\u003emagnetic locks\u003c\/strong\u003e\u003c\/b\u003e\u003cspan\u003e delivers immediate advantages for site security and life safety.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"pt-[9px] pb-0.5 m-0 list-outside list-disc p-0 pt-[5px]\"\u003e\n\u003cli class=\"text-md leading-[24px] font-regular mx-8 my-[5px] [\u0026amp;\u0026gt;ol]:!pt-0 [\u0026amp;\u0026gt;ol]:!pb-0 [\u0026amp;\u0026gt;ul]:!pt-0 [\u0026amp;\u0026gt;ul]:!pb-0\" value=\"1\"\u003e\n\u003cb\u003e\u003cstrong class=\"font-semibold\"\u003eUnmatched Durability:\u003c\/strong\u003e\u003c\/b\u003e\u003cspan\u003e Without physical latches or springs, \u003c\/span\u003e\u003cb\u003e\u003cstrong class=\"font-semibold\"\u003emaglocks\u003c\/strong\u003e\u003c\/b\u003e\u003cspan\u003e suffer virtually zero mechanical wear and tear. They survive thousands of door cycles effortlessly, drastically reducing your maintenance costs.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"text-md leading-[24px] font-regular mx-8 my-[5px] [\u0026amp;\u0026gt;ol]:!pt-0 [\u0026amp;\u0026gt;ol]:!pb-0 [\u0026amp;\u0026gt;ul]:!pt-0 [\u0026amp;\u0026gt;ul]:!pb-0\" value=\"2\"\u003e\n\u003cb\u003e\u003cstrong class=\"font-semibold\"\u003eHigh Holding Force:\u003c\/strong\u003e\u003c\/b\u003e\u003cspan\u003e A powered electromagnet holds the armature plate with immense strength. Once locked, the door becomes incredibly difficult to force open.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"text-md leading-[24px] font-regular mx-8 my-[5px] [\u0026amp;\u0026gt;ol]:!pt-0 [\u0026amp;\u0026gt;ol]:!pb-0 [\u0026amp;\u0026gt;ul]:!pt-0 [\u0026amp;\u0026gt;ul]:!pb-0\" value=\"3\"\u003e\n\u003cb\u003e\u003cstrong class=\"font-semibold\"\u003eFail-Safe Nature:\u003c\/strong\u003e\u003c\/b\u003e\u003cspan\u003e UK fire regulations strictly require fail-safe locks on emergency escape routes. \u003c\/span\u003e\u003cb\u003e\u003cstrong class=\"font-semibold\"\u003eMaglocks\u003c\/strong\u003e\u003c\/b\u003e\u003cspan\u003e naturally drop power and unlock instantly when you cut the electrical feed or trigger the fire alarm, ensuring occupants can evacuate safely.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"font-semibold pdf-heading-class-replace pb-0.5 text-xl leading-[40px] [\u0026amp;:not(:first-child)]:pt-[21px] [\u0026amp;_.underline]:underline-offset-[6px] [\u0026amp;_a]:underline-offset-[6px]\"\u003e\u003cspan\u003eExplore Our Types of Magnetic Locks\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"text-md leading-[24px] font-regular pt-[9px] pb-0.5\"\u003e\u003cspan\u003eDifferent door frames require specific locking footprints. We stock a comprehensive selection to fit your exact site requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"font-semibold pdf-heading-class-replace pb-0.5 text-lg leading-[30px] [\u0026amp;:not(:first-child)]:pt-[15px] [\u0026amp;_.underline]:underline-offset-[6px] [\u0026amp;_a]:underline-offset-[6px]\"\u003e\u003cspan\u003eStandard Maglocks\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"text-md leading-[24px] font-regular pt-[9px] pb-0.5\"\u003e\u003cspan\u003eThese heavy-duty units are the backbone of commercial security. You fit standard \u003c\/span\u003e\u003cb\u003e\u003cstrong class=\"font-semibold\"\u003emagnetic locks\u003c\/strong\u003e\u003c\/b\u003e\u003cspan\u003e to main entrances, heavy timber doors, and external perimeter gates.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"font-semibold pdf-heading-class-replace pb-0.5 text-lg leading-[30px] [\u0026amp;:not(:first-child)]:pt-[15px] [\u0026amp;_.underline]:underline-offset-[6px] [\u0026amp;_a]:underline-offset-[6px]\"\u003e\u003cspan\u003eSlimline Maglocks\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"text-md leading-[24px] font-regular pt-[9px] pb-0.5\"\u003e\u003cspan\u003eWhen space is tight or aesthetics matter, slimline models offer the perfect solution. They deliver robust security while fitting neatly onto narrow door frames, UPVC entries, and glass doors.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"font-semibold pdf-heading-class-replace pb-0.5 text-lg leading-[30px] [\u0026amp;:not(:first-child)]:pt-[15px] [\u0026amp;_.underline]:underline-offset-[6px] [\u0026amp;_a]:underline-offset-[6px]\"\u003e\u003cspan\u003eDouble Maglocks\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"text-md leading-[24px] font-regular pt-[9px] pb-0.5\"\u003e\u003cspan\u003eSecuring double doors requires a unified approach. Double \u003c\/span\u003e\u003cb\u003e\u003cstrong class=\"font-semibold\"\u003emaglocks\u003c\/strong\u003e\u003c\/b\u003e\u003cspan\u003e house two powerful electromagnets in a single sleek housing. This allows you to secure both door leaves simultaneously from a single cable run.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 class=\"font-semibold pdf-heading-class-replace pb-0.5 text-xl leading-[40px] [\u0026amp;:not(:first-child)]:pt-[21px] [\u0026amp;_.underline]:underline-offset-[6px] [\u0026amp;_a]:underline-offset-[6px]\"\u003e\u003cspan\u003eChoosing the Right Holding Force: 600lb vs 1200lb\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"text-md leading-[24px] font-regular pt-[9px] pb-0.5\"\u003e\u003cspan\u003eSpecifying the correct holding force ensures your door resists forced entry effectively.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"pt-[9px] pb-0.5 m-0 list-outside list-disc p-0 pt-[5px]\"\u003e\n\u003cli class=\"text-md leading-[24px] font-regular mx-8 my-[5px] [\u0026amp;\u0026gt;ol]:!pt-0 [\u0026amp;\u0026gt;ol]:!pb-0 [\u0026amp;\u0026gt;ul]:!pt-0 [\u0026amp;\u0026gt;ul]:!pb-0\" value=\"1\"\u003e\n\u003cb\u003e\u003cstrong class=\"font-semibold\"\u003e600lb Holding Force:\u003c\/strong\u003e\u003c\/b\u003e\u003cspan\u003e These are ideal for internal office doors, stockrooms, and standard residential access points. They provide ample resistance against casual intrusion while keeping the hardware footprint small.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"text-md leading-[24px] font-regular mx-8 my-[5px] [\u0026amp;\u0026gt;ol]:!pt-0 [\u0026amp;\u0026gt;ol]:!pb-0 [\u0026amp;\u0026gt;ul]:!pt-0 [\u0026amp;\u0026gt;ul]:!pb-0\" value=\"2\"\u003e\n\u003cb\u003e\u003cstrong class=\"font-semibold\"\u003e1200lb Holding Force:\u003c\/strong\u003e\u003c\/b\u003e\u003cspan\u003e For external main entrances, heavy steel doors, and high-risk commercial perimeters, you must step up to 1200lb. This massive holding force prevents severe physical attacks and ensures your building perimeter remains completely secure.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"font-semibold pdf-heading-class-replace pb-0.5 text-xl leading-[40px] [\u0026amp;:not(:first-child)]:pt-[21px] [\u0026amp;_.underline]:underline-offset-[6px] [\u0026amp;_a]:underline-offset-[6px]\"\u003e\u003cspan\u003eMagnetic Locks FAQs\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"text-md leading-[24px] font-regular pt-[9px] pb-0.5\"\u003e\u003cb\u003e\u003cstrong class=\"font-semibold\"\u003eQ: What is the exact difference between a 600lb and a 1200lb maglock?\u003c\/strong\u003e\u003c\/b\u003e\u003cbr\u003e\u003cspan\u003eA: The difference lies entirely in the holding force of the electromagnet. A 600lb maglock provides more than enough resistance for internal office doors, retail stockrooms, and standard residential entrances. However, if you are securing an external perimeter, a heavy steel door, or a high-risk commercial entrance, you must step up to a 1200lb lock. This massive holding force prevents severe physical attacks and ensures your \u003c\/span\u003e\u003cb\u003e\u003cstrong class=\"font-semibold\"\u003eaccess and control\u003c\/strong\u003e\u003c\/b\u003e\u003cspan\u003e perimeter remains completely secure.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"text-md leading-[24px] font-regular pt-[9px] pb-0.5\"\u003e\u003cb\u003e\u003cstrong class=\"font-semibold\"\u003eQ: What happens to my magnetic lock during a power cut?\u003c\/strong\u003e\u003c\/b\u003e\u003cbr\u003e\u003cspan\u003eA: Magnetic locks are strictly fail-safe, meaning they require continuous electrical power to stay locked. If the mains power drops, the magnet loses its holding force and the door opens freely. To keep your premises secure during a blackout, we highly recommend fitting a lead-acid battery backup inside your power supply unit. This ensures your \u003c\/span\u003e\u003cb\u003e\u003cstrong class=\"font-semibold\"\u003eaccess and control\u003c\/strong\u003e\u003c\/b\u003e\u003cspan\u003e network continues to operate flawlessly until mains power returns.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"text-md leading-[24px] font-regular pt-[9px] pb-0.5\"\u003e\u003cb\u003e\u003cstrong class=\"font-semibold\"\u003eQ: Are maglocks fully compliant with UK fire safety regulations?\u003c\/strong\u003e\u003c\/b\u003e\u003cbr\u003e\u003cspan\u003eA: Yes, they are highly compliant when installed correctly. Because maglocks are naturally fail-safe, they are the mandatory choice for designated emergency escape routes. To meet strict UK fire safety rules, you must wire your maglock to a green emergency break-glass switch on the secure side of the door. Furthermore, you should link the power supply directly to the building's fire alarm panel to ensure the doors unlock automatically during an emergency. With over 16 years of trade experience, we strictly champion these life-saving installation standards.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"text-md leading-[24px] font-regular pt-[9px] pb-0.5\"\u003e\u003cb\u003e\u003cstrong class=\"font-semibold\"\u003eQ: How do I maintain my maglocks to prevent them from sticking or buzzing?\u003c\/strong\u003e\u003c\/b\u003e\u003cbr\u003e\u003cspan\u003eA: Dirt and debris are the main causes of a buzzing or poorly holding maglock. You should routinely wipe down the face of the electromagnet and the metal armature plate with a soft cloth and a non-abrasive cleaner. Never paint the surface of the magnet or the plate. Additionally, ensure the armature plate retains a slight movement on its mounting bolt. The included rubber washer allows the plate to float slightly, ensuring it aligns perfectly flat against the magnet every time the door closes.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"text-md leading-[24px] font-regular pt-[9px] pb-0.5\"\u003e\u003cb\u003e\u003cstrong class=\"font-semibold\"\u003eQ: Can I install a maglock on a frameless glass door or a UPVC frame?\u003c\/strong\u003e\u003c\/b\u003e\u003cbr\u003e\u003cspan\u003eA: You can fit our maglocks to almost any door material using the correct mounting accessories. While wooden frames often allow for direct surface mounting, UPVC and outward-opening doors usually require a Z and L bracket set to achieve the correct angle. If you are securing a frameless glass door, you simply use a specialised U-bracket to clamp the armature plate safely to the glass without drilling. This versatility makes maglocks a brilliant addition to any modern \u003c\/span\u003e\u003cb\u003e\u003cstrong class=\"font-semibold\"\u003eaccess and control\u003c\/strong\u003e\u003c\/b\u003e\u003cspan\u003e setup.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 class=\"font-semibold pdf-heading-class-replace pb-0.5 text-xl leading-[40px] [\u0026amp;:not(:first-child)]:pt-[21px] [\u0026amp;_.underline]:underline-offset-[6px] [\u0026amp;_a]:underline-offset-[6px]\"\u003e\u003cspan\u003eWhy Door Entry Online is Your Ideal Partner\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"text-md leading-[24px] font-regular pt-[9px] pb-0.5\"\u003e\u003cspan\u003eWe do much more than simply ship boxes. We partner with you to ensure your installation succeeds safely and profitably.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"pt-[9px] pb-0.5 m-0 list-outside list-disc p-0 pt-[5px]\"\u003e\n\u003cli class=\"text-md leading-[24px] font-regular mx-8 my-[5px] [\u0026amp;\u0026gt;ol]:!pt-0 [\u0026amp;\u0026gt;ol]:!pb-0 [\u0026amp;\u0026gt;ul]:!pt-0 [\u0026amp;\u0026gt;ul]:!pb-0\" value=\"1\"\u003e\n\u003cb\u003e\u003cstrong class=\"font-semibold\"\u003e40+ Years of Installer Experience:\u003c\/strong\u003e\u003c\/b\u003e\u003cspan\u003e We founded this business after working directly as professional installers. We only supply \u003c\/span\u003e\u003cb\u003e\u003cstrong class=\"font-semibold\"\u003emagnetic locks\u003c\/strong\u003e\u003c\/b\u003e\u003cspan\u003e that we trust completely. We strip out cheap, unreliable hardware so you only buy components that survive the real world.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"text-md leading-[24px] font-regular mx-8 my-[5px] [\u0026amp;\u0026gt;ol]:!pt-0 [\u0026amp;\u0026gt;ol]:!pb-0 [\u0026amp;\u0026gt;ul]:!pt-0 [\u0026amp;\u0026gt;ul]:!pb-0\" value=\"2\"\u003e\n\u003cb\u003e\u003cstrong class=\"font-semibold\"\u003eUK-Based Technical Support:\u003c\/strong\u003e\u003c\/b\u003e\u003cspan\u003e If you face a tricky door frame or a complex wiring challenge on-site, our trade experts are ready to help. We provide practical, straightforward advice to keep your project moving forward without delays.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"font-semibold pdf-heading-class-replace pb-0.5 text-xl leading-[40px] [\u0026amp;:not(:first-child)]:pt-[21px] [\u0026amp;_.underline]:underline-offset-[6px] [\u0026amp;_a]:underline-offset-[6px]\"\u003e\u003cspan\u003eMaximise Your Margins with Trade Discounts\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"text-md leading-[24px] font-regular pt-[9px] pb-0.5\"\u003e\u003cspan\u003eWe actively support trade professionals and property managers who buy in volume. When you order your \u003c\/span\u003e\u003cb\u003e\u003cstrong class=\"font-semibold\"\u003emaglocks\u003c\/strong\u003e\u003c\/b\u003e\u003cspan\u003e with us, you instantly access tiered discounts at the checkout:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"pt-[9px] pb-0.5 m-0 list-outside list-disc p-0 pt-[5px]\"\u003e\n\u003cli class=\"text-md leading-[24px] font-regular mx-8 my-[5px] [\u0026amp;\u0026gt;ol]:!pt-0 [\u0026amp;\u0026gt;ol]:!pb-0 [\u0026amp;\u0026gt;ul]:!pt-0 [\u0026amp;\u0026gt;ul]:!pb-0\" value=\"1\"\u003e\n\u003cspan\u003eSave \u003c\/span\u003e\u003cb\u003e\u003cstrong class=\"font-semibold\"\u003e3%\u003c\/strong\u003e\u003c\/b\u003e\u003cspan\u003e on orders over £300\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"text-md leading-[24px] font-regular mx-8 my-[5px] [\u0026amp;\u0026gt;ol]:!pt-0 [\u0026amp;\u0026gt;ol]:!pb-0 [\u0026amp;\u0026gt;ul]:!pt-0 [\u0026amp;\u0026gt;ul]:!pb-0\" value=\"2\"\u003e\n\u003cspan\u003eSave \u003c\/span\u003e\u003cb\u003e\u003cstrong class=\"font-semibold\"\u003e10%\u003c\/strong\u003e\u003c\/b\u003e\u003cspan\u003e on orders over £750\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"text-md leading-[24px] font-regular mx-8 my-[5px] [\u0026amp;\u0026gt;ol]:!pt-0 [\u0026amp;\u0026gt;ol]:!pb-0 [\u0026amp;\u0026gt;ul]:!pt-0 [\u0026amp;\u0026gt;ul]:!pb-0\" value=\"3\"\u003e\n\u003cspan\u003eSave a massive \u003c\/span\u003e\u003cb\u003e\u003cstrong class=\"font-semibold\"\u003e15%\u003c\/strong\u003e\u003c\/b\u003e\u003cspan\u003e on orders over £1,500\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"text-md leading-[24px] font-regular pt-[9px] pb-0.5\"\u003e\u003cspan\u003eBrowse our full collection of professional \u003c\/span\u003e\u003cb\u003e\u003cstrong class=\"font-semibold\"\u003emagnetic locks\u003c\/strong\u003e\u003c\/b\u003e\u003cspan\u003e below and equip your doors with reliable, trade-approved security hardware today.\u003c\/span\u003e\u003c\/p\u003e","products":[{"product_id":"external-magnetic-lock-em800","title":"Magnetic Lock EM800","description":"\u003ch2\u003eEM800 Surface Mount Magnetic Lock (Monitored)\u003c\/h2\u003e\n\u003cp\u003eThe EM800 is a stainless steel, side mounted external magnetic lock designed for 12\/24V DC systems. Ideal for uPVC, timber, or metal doors, it offers robust security for both internal and external use. It can be installed for side or top mounting, with an 'L' bracket typically required for outward-opening doors.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHolding Force:\u003c\/strong\u003e 382kg (800 lbs)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMonitored Output:\u003c\/strong\u003e This model features a built-in Hall Effect sensor with Normally Open (N\/O) and Normally Closed (N\/C) contacts. This allows you to integrate the lock with alarm systems, sounders, buzzers, or indicator lights to confirm if the door is securely locked or unlocked.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Input:\u003c\/strong\u003e 12V or 24V DC (selectable via wiring)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Draw:\u003c\/strong\u003e 480mA @ 12V DC \/ 240mA @ 24V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMagnet Dimensions:\u003c\/strong\u003e 220mm (L) x 46mm (W) x 28mm (D)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArmature Plate Dimensions:\u003c\/strong\u003e 180mm (L) x 44mm (W) x 12mm (D)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMagnet Weight:\u003c\/strong\u003e 1.45kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArmature Weight:\u003c\/strong\u003e 0.700kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTroubleshooting \u0026amp; FAQs\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is the magnet running hot?\u003c\/strong\u003e \u003cbr\u003e\"Power to Lock\" devices like magnetic locks will naturally feel warm due to the constant power they require. However, excessive heat is usually caused by:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Mismatch:\u003c\/strong\u003e Using a 24V DC power supply for a magnet wired for 12V DC operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsufficient Current:\u003c\/strong\u003e The power supply may not provide enough amperage, or a long cable run with an inadequate wire gauge can cause a voltage drop, forcing the magnet to work harder and overheat.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is the armature plate vibrating?\u003c\/strong\u003e \u003cbr\u003eThis typically points to an under-rated or faulty power supply. It can also occur if the magnet is wired for 24V DC but is connected to a 12V DC power supply.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy won't the magnet lock properly?\u003c\/strong\u003e \u003cbr\u003eThe most common reasons for a weak hold are:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eMisalignment:\u003c\/strong\u003e The armature plate is not correctly aligned with the magnet's surface.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Issues:\u003c\/strong\u003e The power supply is faulty, under-rated, or there is a voltage mismatch (e.g., 12V supply for a 24V setup).\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation \u0026amp; Maintenance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eTech Tips:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerify Wiring:\u003c\/strong\u003e Before powering on, double-check that the wiring connections match your chosen power supply voltage (12V or 24V). Incorrect wiring can cause the lock to overheat, fail to engage, and eventually damage the system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRegular Cleaning:\u003c\/strong\u003e Periodically clean the surfaces of both the magnet and the armature plate with a light oil to ensure optimal performance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFixing Brackets (Sold Separately):\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e'L' Bracket:\u003c\/strong\u003e Typically used for outward-opening doors.\n\u003cul\u003e\n\u003cli\u003eDimensions: 220mm (L) x (50mm x 34mm) (H)\u003c\/li\u003e\n\u003cli\u003eWeight: 0.500kg\u003cbr\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e'Z' Bracket:\u003c\/strong\u003e Typically used for inward-opening doors. This bracket allows for fine-tuning the armature plate's position and angle.\n\u003cul\u003e\n\u003cli\u003eDimensions: 182mm (W) x 2 x (50mm x 50mm) (H)\u003c\/li\u003e\n\u003cli\u003eWeight: 0.600kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eWhat's Included\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Magnetic Lock\u003c\/li\u003e\n\u003cli\u003e1 x Armature Plate\u003c\/li\u003e\n\u003cli\u003e1 x Top-Fixing Plate\u003c\/li\u003e\n\u003cli\u003e1 x Fixing Kit\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Door Entry Online","offers":[{"title":"Default Title","offer_id":56327220134152,"sku":"EM800","price":71.96,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1034\/8294\/9896\/files\/external-magnetic-lock-em800.jpg?v=1791732986"},{"product_id":"external-magnetic-lock-em800ss-ss-800","title":"Magnetic Lock EM800SS","description":"\u003ch2\u003eEM800SS Surface Mount External Magnetic Lock (Monitored)\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e The EM800SS external magnetic lock is a versatile 12\/24V DC stainless steel magnetic lock designed for external use. It offers a strong holding force of 382kg (800lbs) and can be mounted on the side, face, or top of uPVC, timber, or metal doors due to two side \u0026amp; four face fixing holes.\u003c\/p\u003e\n\u003cp\u003eAs a monitored lock, the EM800SS allows you to confirm its status (locked or unlocked). It features a built-in Hall Effect sensor with voltage-free Normally Open (N\/O) and Normally Closed (N\/C) contacts. These contacts can be connected to external devices like sounders, buzzers, or alarm systems to signal when the magnet and armature plate are separated. Please note, this model does not have an LED status indicator.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHolding Force:\u003c\/strong\u003e 382kg (800lbs)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 12V \/ 24V DC (selectable)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUse:\u003c\/strong\u003e Suitable for internal and external doors\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Surface or side mount (requires appropriate brackets)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMonitoring:\u003c\/strong\u003e Includes N\/O \u0026amp; N\/C voltage-free contacts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Input:\u003c\/strong\u003e 12V \/ 24V DC (selectable via wiring)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Draw:\u003c\/strong\u003e 480mA @ 12V DC | 240mA @ 24V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMagnet Dimensions:\u003c\/strong\u003e 220mm (L) x 46mm (W) x 28mm (D)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArmature Plate Dimensions:\u003c\/strong\u003e 180mm (L) x 44mm (W) x 12mm (D)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMagnet Weight:\u003c\/strong\u003e 1.45kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArmature Weight:\u003c\/strong\u003e 0.700kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003eFrequently Asked Questions (FAQs)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: The magnet feels very warm, almost hot. Is this normal?\u003cbr\u003e\u003c\/strong\u003e\"Power-to-lock\" devices like magnetic locks require constant power and can naturally run warm. However, excessive heat can be caused by:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eIncorrect Voltage:\u003c\/strong\u003e A 12V magnet connected to a 24V power supply.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsufficient Amperage:\u003c\/strong\u003e The power supply is not providing enough current.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Drop:\u003c\/strong\u003e A long cable run with an inadequate wire gauge is causing a loss of current.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cstrong\u003eQ: The armature plate is vibrating. What's causing this?\u003cbr\u003e\u003c\/strong\u003eVibration is typically caused by either a faulty\/under-rated power supply or by powering a 24V magnet with a 12V supply.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: The magnet isn't locking properly. Why?\u003cbr\u003e\u003c\/strong\u003eThe most common causes are:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eMisalignment:\u003c\/strong\u003e The armature plate is not correctly aligned with the magnetic lock.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Issues:\u003c\/strong\u003e The power supply is faulty, under-rated, or providing the wrong voltage (e.g., 12V for a 24V lock).\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical \u0026amp; Installation Tips\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Selection:\u003c\/strong\u003e Before powering on, double-check that the wiring connections match your 12V or 24V DC power supply. Incorrect wiring can cause overheating, locking failure, and eventual damage to the system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaintenance:\u003c\/strong\u003e Periodically clean the surfaces of both the magnet and armature plate with a light oil to ensure optimal performance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003eBrackets (Sold Separately)\u003c\/strong\u003e Please consider if you require mounting brackets for your installation.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e'L' Bracket:\u003c\/strong\u003e Typically used for outward-opening doors.\n\u003cul\u003e\n\u003cli\u003eWeight: 0.500kg\u003c\/li\u003e\n\u003cli\u003eDimensions: 220mm (L) x (50 x 34mm) (H) x 6mm (D)\u003c\/li\u003e\n\u003cli\u003eAdjustment: Offers 23mm of forward\/backward adjustment.\u003cbr\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e'Z' Bracket:\u003c\/strong\u003e Required for inward-opening doors to mount the armature plate.\n\u003cul\u003e\n\u003cli\u003eWeight: 0.600kg\u003c\/li\u003e\n\u003cli\u003eDimensions: 182mm (W) x 2 x (50 x 50mm) (H) x 6mm (D)\u003c\/li\u003e\n\u003cli\u003eAdjustment: Allows for up to 40mm of forward\/backward adjustment and 32 degrees of angle adjustment for precise alignment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003eWhat's Included\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Magnetic Lock\u003c\/li\u003e\n\u003cli\u003e1 x Top Fixing Plate\u003c\/li\u003e\n\u003cli\u003e1 x Armature Plate\u003c\/li\u003e\n\u003cli\u003e1 x Fixing Kit\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Door Entry Online","offers":[{"title":"Default Title","offer_id":56327220396296,"sku":"SS-800","price":78.82,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1034\/8294\/9896\/files\/external-magnetic-lock-em800ss.jpg?v=1791733122"},{"product_id":"external-magnetic-lock-gl1200-ugl1200ntbr","title":"Magnetic Lock GL1200","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eGL1200 Surface Mount External Magnetic Lock (Monitored)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe GL1200 is a robust 12\/24V DC surface-mounted magnetic lock featuring a male conduit thread. It offers a powerful holding force of 544kg, ensuring reliable security. Designed for versatility, it includes both side and face mounting holes suitable for uPVC, timber, or metal doors in internal or external settings.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMonitoring Feature:\u003c\/strong\u003e This monitored version allows you to confirm the lock's status (locked or unlocked). It contains a set of voltage-free Hall Effect contacts (Normally Open \u0026amp; Normally Closed) that can be connected to external devices like sounders, buzzers, alarms, or indicator lights to signal when the lock is disengaged. Please note, this model does not have a built-in LED indicator.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHolding Force:\u003c\/strong\u003e 544kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMagnet Weight:\u003c\/strong\u003e 2.97 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArmature Weight:\u003c\/strong\u003e 1.53 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Input:\u003c\/strong\u003e 12V DC \/ 24V DC (selectable via wiring)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHolding Force:\u003c\/strong\u003e 544kg (1200lbs)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Draw:\u003c\/strong\u003e 500mA @ 12V DC | 250mA @ 24V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMagnet Dimensions:\u003c\/strong\u003e 220mm (L) x 62mm (W) x 40mm (D)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArmature Plate Dimensions:\u003c\/strong\u003e 185mm (L) x 62mm (W) x 16mm (D)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is the magnet running hot?\u003c\/strong\u003e \"Power to Lock\" devices like magnetic locks require constant power and can naturally run warm. However, excessive heat is often caused by:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eIncorrect Voltage:\u003c\/strong\u003e Using a 24V DC power supply for a magnet configured for 12V DC operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsufficient Current:\u003c\/strong\u003e The power supply doesn't provide enough amperage, or there's a significant current drop from a long cable run with an inadequate wire gauge.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is the armature plate vibrating?\u003c\/strong\u003e This typically points to an issue with the power supply being faulty or underrated. It can also occur if the magnet is set for 24V DC operation but is connected to a 12V DC power supply.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy won't the magnet lock properly?\u003c\/strong\u003e The most common reasons are:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eMisalignment:\u003c\/strong\u003e The armature plate is not correctly aligned with the magnet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Issues:\u003c\/strong\u003e The power supply is faulty, underrated, or providing the incorrect voltage (e.g., 12V DC for a 24V DC setup).\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003chr\u003e\n\u003ch3\u003eTech Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Selection:\u003c\/strong\u003e Before powering on, double-check that the wiring connections match your power supply (12V DC or 24V DC). Incorrect wiring can cause overheating, locking failure, and eventual damage to the system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaintenance:\u003c\/strong\u003e Periodically clean the surfaces of both the magnet and the armature plate with a light oil to ensure optimal performance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eBrackets\u003c\/h3\u003e\n\u003cp\u003ePlease consider if you need mounting brackets for your installation.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e'L' Bracket:\u003c\/strong\u003e Typically used for outward-opening doors.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.35 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSize:\u003c\/strong\u003e 222mm (L) x 6mm (D) x [62mm x 46mm (H)]\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdjustment:\u003c\/strong\u003e Allows the magnet to be aligned from -0mm to 31mm backward.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e'ZL' Bracket:\u003c\/strong\u003e Typically used for inward-opening doors.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 1.05 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSize:\u003c\/strong\u003e 185mm (L) x 6mm (D) x [63mm (H) x 63mm (H)]\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdjustment:\u003c\/strong\u003e Allows the armature plate to be aligned from -21mm forward to 31mm backward.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eWhat's Included\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Magnetic Lock\u003c\/li\u003e\n\u003cli\u003e1 x Armature Plate\u003c\/li\u003e\n\u003cli\u003e1 x Fixing Kit\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Door Entry Online","offers":[{"title":"Default Title","offer_id":56327220625672,"sku":"UGL1200NTBR","price":79.45,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1034\/8294\/9896\/files\/external-magnetic-lock-ugl1200ntbr-gl1200.jpg?v=1791733972"},{"product_id":"magnetic-lock-gl800-ugl850r","title":"Magnetic Lock GL800","description":"\u003ch2\u003eGL800 Surface Mount External Magnetic Lock (Monitored)\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe GL800 is a versatile 12\/24V DC surface-mount magnetic lock designed for external use. It features a male conduit thread and delivers a strong holding force of 385kg (850lbs). With both side and face mount fixing holes, it offers flexible installation on uPVC, timber, or metal doors.\u003c\/p\u003e\n\u003cp\u003eThis model includes a monitoring function, allowing you to confirm whether the lock is engaged or disengaged. An internal Hall Effect sensor provides voltage-free Normally Open (N\/O) and Normally Closed (N\/C) contacts. These can be connected to an alarm, buzzer, sounder, or light to indicate when the magnet and armature plate are separated.\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHolding Force:\u003c\/strong\u003e 385kg (850lbs)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Input:\u003c\/strong\u003e 12V or 24V DC (selectable via wiring)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Draw:\u003c\/strong\u003e 500mA @ 12V DC | 250mA @ 24V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMagnet Dimensions (with thread):\u003c\/strong\u003e 246mm (L) x 48mm (W) x 30mm (D)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArmature Plate Dimensions:\u003c\/strong\u003e 185mm (L) x 45mm (W) x 14mm (D)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMagnet Weight:\u003c\/strong\u003e 1.760kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArmature Weight:\u003c\/strong\u003e 0.990kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003eFrequently Asked Questions (FAQs) \u0026amp; Troubleshooting\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Why is the magnet running very warm, almost hot?\u003c\/strong\u003e \u003cstrong\u003eA:\u003c\/strong\u003e \"Power to Lock\" devices like magnetic locks require constant power and can naturally run warm. However, excessive heat is usually caused by:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eIncorrect Voltage:\u003c\/strong\u003e A 12V DC magnet connected to a 24V DC power supply.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsufficient Amperage:\u003c\/strong\u003e The power supply is not providing enough current.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Drop:\u003c\/strong\u003e A long cable run with an inadequate wire gauge is causing a loss of current.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cstrong\u003eQ: The armature plate is vibrating. What's causing this?\u003c\/strong\u003e \u003cstrong\u003eA:\u003c\/strong\u003e Vibration is typically due to an under-rated or faulty power supply, or if a 24V DC magnet is being powered by a 12V DC supply.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: The magnet isn't locking properly and the door can be pulled open.\u003c\/strong\u003e \u003cstrong\u003eA:\u003c\/strong\u003e This is often caused by:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoor Alignment:\u003c\/strong\u003e The armature plate is not correctly aligned with the magnetic lock.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Issues:\u003c\/strong\u003e The power supply is faulty, under-rated, or providing the wrong voltage (e.g., 12V DC to a 24V DC lock).\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Tips\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation:\u003c\/strong\u003e Before powering on, double-check that the wiring connections match your chosen 12V or 24V DC power supply. Incorrect wiring can cause the lock to overheat, fail to engage, or lead to eventual system damage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaintenance:\u003c\/strong\u003e Periodically clean the surfaces of both the magnet and the armature plate with a light oil to ensure optimal performance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003eOptional Fixing Brackets\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePlease consider if you need fixing brackets for your installation:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eL-Bracket:\u003c\/strong\u003e Typically used for outward-opening doors.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.500kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSize:\u003c\/strong\u003e 220mm (L) x 6mm (D) x (50 x 34h) mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdjustment:\u003c\/strong\u003e 6 screws allow for 0mm to 23mm of backward\/forward adjustment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eZ-Bracket:\u003c\/strong\u003e Typically used for inward-opening doors.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.600kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSize:\u003c\/strong\u003e 182mm (W) x 6mm (D) x 2 x (50 x 50h) mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdjustment:\u003c\/strong\u003e 6 screws allow for -18mm to 40mm of backward\/forward alignment and angle adjustment up to 32 degrees.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003eWhat's in the Box\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Magnetic Lock\u003c\/li\u003e\n\u003cli\u003e1 x Armature Plate\u003c\/li\u003e\n\u003cli\u003e1 x Fixing Kit\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Door Entry Online","offers":[{"title":"Default Title","offer_id":56327220887816,"sku":"UGL850R","price":72.21,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1034\/8294\/9896\/files\/gl1200_m.jpg?v=1775300081"},{"product_id":"standard-magnetic-lock-1200-u10010","title":"Magnetic Lock 1200","description":"\u003ch2\u003e12\/24V DC Surface Mount Standard Magnetic Lock\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eHolding Force:\u003c\/strong\u003e 544kg (1200lbs)\u003c\/p\u003e\n\u003cp\u003eThis standard magnetic lock offers robust security for internal uPVC, timber, or metal doors\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Voltage:\u003c\/strong\u003e Selectable 12V or 24V DC operation via internal jumper links.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Holding Force:\u003c\/strong\u003e Provides a strong holding force of up to 544kg (1200lbs).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVersatile Mounting:\u003c\/strong\u003e Suitable for surface or side mount fitting on various door types.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Input:\u003c\/strong\u003e 12V \/ 24V DC (selectable)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Draw:\u003c\/strong\u003e 500mA @ 12V DC | 250mA @ 24V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHolding Force:\u003c\/strong\u003e 544kg (1200lbs)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMagnet Dimensions:\u003c\/strong\u003e 267mm (L) x 67mm (W) x 40mm (D)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArmature Plate Dimensions:\u003c\/strong\u003e 185mm (L) x 62mm (W) x 16mm (D)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMagnet Weight:\u003c\/strong\u003e 2.970kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArmature Weight:\u003c\/strong\u003e 1.530kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTroubleshooting \u0026amp; FAQs\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is the magnet running hot?\u003c\/strong\u003e \u003cbr\u003e\"Power to Lock\" devices require constant power and can run warm. However, excessive heat is often caused by:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Mismatch:\u003c\/strong\u003e Using a 24V DC power supply for a magnet set to 12V DC operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsufficient Amperage:\u003c\/strong\u003e The power supply is not providing enough current.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Drop:\u003c\/strong\u003e Long cable runs with an inadequate wire gauge can cause the magnet to run hot due to insufficient current.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is the armature plate vibrating?\u003c\/strong\u003e \u003cbr\u003eThis is typically due to an underrated or faulty power supply, or if the magnet is set for 24V DC but is receiving only 12V DC.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy won't the magnet lock properly?\u003c\/strong\u003e \u003cbr\u003eThe most common causes are:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMisalignment:\u003c\/strong\u003e The armature plate is not correctly aligned with the magnetic lock.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Issues:\u003c\/strong\u003e A faulty or underrated power supply, or a voltage mismatch (e.g., 12V DC power for a 24V DC setting).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation \u0026amp; Technical Tips\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerify Voltage:\u003c\/strong\u003e Before powering on, double-check that the wiring connections match your chosen power supply (12V DC or 24V DC). Failure to do so can cause the lock to overheat, fail to lock correctly, and eventually damage the system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRegular Maintenance:\u003c\/strong\u003e Periodically clean the surfaces of both the magnet and the armature plate with a light oil to ensure optimal performance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eOptional Brackets\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003ePlease consider if you require mounting brackets for your installation.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e'L' Bracket:\u003c\/strong\u003e Typically used for outward-opening doors.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.450kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSize:\u003c\/strong\u003e 267mm (L) x 6mm (D) x (51mm x 51mm) (H)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdjustment:\u003c\/strong\u003e 8-screw adjustment allows the magnet to be aligned from -6mm forward to +19mm backward.\u003cbr\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e'ZL' Bracket:\u003c\/strong\u003e Typically used for inward-opening doors.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 1.05kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSize:\u003c\/strong\u003e 185mm (L) x 6mm (D) x 2 x (63mm x 63mm) (H)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdjustment:\u003c\/strong\u003e 12-screw adjustment allows the armature plate to be aligned from -21mm forward to +31mm backward.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eWhat's Included?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Magnetic Lock\u003c\/li\u003e\n\u003cli\u003e1 x Armature Plate\u003c\/li\u003e\n\u003cli\u003e1 x Fixing Kit\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Door Entry Online","offers":[{"title":"Default Title","offer_id":56327221215496,"sku":"U10010","price":55.77,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1034\/8294\/9896\/files\/standard-magnetic-lock-u10010-1200.jpg?v=1791731408"},{"product_id":"magnetic-lock-1200-led-u10020","title":"Magnetic Lock 1200-LED","description":"\u003ch2\u003e12\/24V DC Surface Mount Magnetic Lock (1200-LED, Monitored)\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eHolding Force:\u003c\/strong\u003e 544kg\u003c\/p\u003e\n\u003cp\u003eA powerful and reliable locking solution, this surface-mounted magnetic lock is ideal for internal uPVC, timber, or metal doors. It operates on either 12V or 24V DC power and features a robust holding force of 544kg (1200lbs)\u003cbr\u003e\u003cbr\u003eThe monitored option for magnetic locks simply means that the magnet status of it can be monitored to determine and confirm if the magnet is locked or unlocked. \u003cbr\u003eInside the magnet is a set of voltage free Hall Effect contacts providing Normally Open and Normally Closed contacts (N\/O \u0026amp; N\/C)\u003c\/p\u003e\n\u003cp\u003eWith these contacts you can connect them to a sounder, buzzer, alarm system, light or anything else that would require a voltage set of free contacts to trigger the device when the magnet and the armature plate is separated\u003c\/p\u003e\n\u003cp\u003eSome monitored magnetic locks will also have a dual red\/green LED to indicate its open or closed status. The 1200-LED - (Monitored) has LED indication\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLED Indicator:\u003c\/strong\u003e A dual red\/green LED provides a clear visual confirmation of the magnetic lock's open or closed status.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Holding Force:\u003c\/strong\u003e With a holding force of 544kg (1200lbs), this lock ensures a secure closure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdjustable Voltage:\u003c\/strong\u003e Easily switch between 12V and 24V DC operation using internal jumper links.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Input:\u003c\/strong\u003e 12V \/ 24V DC (selectable)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHolding Force:\u003c\/strong\u003e 544kg (1200lbs)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Draw:\u003c\/strong\u003e 500mA @ 12V DC | 250mA @ 24V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMagnet Dimensions:\u003c\/strong\u003e 267mm (L) x 67mm (W) x 40mm (D)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArmature Plate Dimensions:\u003c\/strong\u003e 185mm (L) x 62mm (W) x 16mm (D)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMagnet Weight:\u003c\/strong\u003e 2.970kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArmature Plate Weight:\u003c\/strong\u003e 1.530kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eTroubleshooting \u0026amp; FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is the magnet getting hot?\u003c\/strong\u003e \u003cbr\u003e\"Power to Lock\" devices require constant power and can run warm. However, excessive heat is usually caused by:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eRunning a 12V magnet on a 24V power supply.\u003c\/li\u003e\n\u003cli\u003eAn insufficient power supply (amperage is too low).\u003c\/li\u003e\n\u003cli\u003eA significant voltage drop due to long cable runs with inadequately sized wire.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is the armature plate vibrating?\u003c\/strong\u003e \u003cbr\u003eThis is typically caused by a faulty or underrated power supply, or by using a 12V power supply for a magnet set to 24V DC operation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy won't the magnet lock properly?\u003c\/strong\u003e \u003cbr\u003eThe most common causes are:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eIncorrect alignment between the armature plate and the magnet.\u003c\/li\u003e\n\u003cli\u003eA faulty or underrated power supply.\u003c\/li\u003e\n\u003cli\u003eA voltage mismatch (e.g., a 12V supply for a 24V magnet).\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation \u0026amp; Tech Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerify Voltage:\u003c\/strong\u003e Before powering on, double-check that the wiring connections match your selected 12V or 24V power supply. Failure to do so can cause the lock to overheat, fail to engage, and eventually damage the system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRegular Maintenance:\u003c\/strong\u003e Periodically clean the surfaces of both the magnet and the armature plate with a light oil to ensure optimal performance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eOptional Brackets\u003c\/h3\u003e\n\u003cp\u003ePlease consider if you require mounting brackets for your installation:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e'L' Bracket:\u003c\/strong\u003e Typically used for outward-opening doors.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.450kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 267mm (L) x 6mm (D) x (51mm x 51mm H)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e'ZL' Bracket:\u003c\/strong\u003e Typically used for inward-opening doors.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 1.05kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 185mm (L) x 6mm (D) x 2 x (63mm H x 63mm H)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eWhat's Included?\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Magnetic Lock\u003c\/li\u003e\n\u003cli\u003e1 x Armature Plate\u003c\/li\u003e\n\u003cli\u003e1 x Fixing Kit\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Door Entry Online","offers":[{"title":"Default Title","offer_id":56327221543176,"sku":"U10020","price":57.61,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1034\/8294\/9896\/files\/standard-magnetic-lock-u10020-1200-led.jpg?v=1791731464"},{"product_id":"double-mini-magnetic-lock-600-d-u10004","title":"Magnetic Lock 600-D","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eProduct:\u003c\/strong\u003e 12\/24V DC Surface Mount Slimline Double Mini Magnetic Lock (600-D)\u003c\/p\u003e\n\u003cp\u003eThis slimline double magnetic lock is designed for surface or side mounting on uPVC, timber, or metal doors. It's an ideal choice for internal applications requiring a secure and reliable locking mechanism.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHolding Force:\u003c\/strong\u003e 2 x 272kg (600lbs)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMagnet Weight:\u003c\/strong\u003e 2 x 1.253kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArmature Weight:\u003c\/strong\u003e 2 x 0.597kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Input:\u003c\/strong\u003e Selectable 12V or 24V DC via internal jumper links.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Draw:\u003c\/strong\u003e 1000mA @ 12V DC | 500mA @ 24V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHolding Force:\u003c\/strong\u003e 2 x 272kg (2 x 600lbs)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMagnet Dimensions:\u003c\/strong\u003e 500mm (L) x 42mm (W) x 26mm (D)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArmature Plate Dimensions:\u003c\/strong\u003e 180mm (L) x 38mm (W) x 12mm (D) each\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eFAQs \u0026amp; Troubleshooting\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is the magnet running warm or hot?\u003c\/strong\u003e \u003cbr\u003e\"Power to Lock\" devices like magnetic locks require constant power, which generates some heat. However, excessive heat is usually caused by:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Mismatch:\u003c\/strong\u003e The magnet is set to 12V DC but is connected to a 24V DC power supply.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsufficient Amperage:\u003c\/strong\u003e The power supply isn't providing enough current, causing the magnet to run hot.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Drop:\u003c\/strong\u003e A long cable run with an inadequate wire gauge can reduce the current reaching the magnet, causing it to heat up.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is the armature plate vibrating?\u003c\/strong\u003e \u003cbr\u003eThis is typically caused by a faulty or underrated power supply, or by running a 24V DC magnet on a 12V DC power supply.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy won't the magnet lock properly?\u003c\/strong\u003e \u003cbr\u003eThe most common reasons are:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eMisalignment:\u003c\/strong\u003e The armature plate is not correctly aligned with the magnetic lock.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Issues:\u003c\/strong\u003e The power supply is faulty, underrated, or providing the incorrect voltage (e.g., 12V for a 24V magnet).\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical \u0026amp; Installation Tips\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Selection:\u003c\/strong\u003e Before powering on, always verify that the wiring connections match your selected power supply (12V or 24V). Failure to do so can cause the lock to overheat or fail, potentially damaging the entire system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaintenance:\u003c\/strong\u003e Periodically clean the surfaces of the magnet and armature plate with a light oil to ensure optimal performance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eOptional Brackets\u003c\/h2\u003e\n\u003cp\u003eConsider whether you need mounting brackets for your installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eL Bracket (for outward-opening doors):\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.300kg x 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 250mm (L) x 4mm (D) x 38mm (H)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdjustment:\u003c\/strong\u003e Features 8 screws for alignment, allowing movement from -6mm forward to 19mm backward.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eZL Bracket (for inward-opening doors):\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.550kg x 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 180mm (L) x 4mm (D) x 46mm (H)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdjustment:\u003c\/strong\u003e Features 4 screws for alignment, allowing movement from -9mm forward to 31mm backward.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eWhat's Included\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Double Magnetic Lock\u003c\/li\u003e\n\u003cli\u003e2 x Armature Plates\u003c\/li\u003e\n\u003cli\u003e1 x Fixing Kit\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Door Entry Online","offers":[{"title":"Default Title","offer_id":56327222001928,"sku":"U10004","price":51.88,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1034\/8294\/9896\/files\/magnetic-lock-u10004-600-d.jpg?v=1791731233"},{"product_id":"double-min-magnetic-lock-600-d-led-u10005","title":"Magnetic Lock 600-D-LED","description":"\u003cp\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct:\u003c\/strong\u003e 12\/24V DC Surface-Mount Slimline Double Mini Magnetic Lock (Monitored) \u003cstrong\u003eModel:\u003c\/strong\u003e 600-D-LED \u003cstrong\u003eHolding Force:\u003c\/strong\u003e 2 x 272kg \u003cstrong\u003eMagnet Weight:\u003c\/strong\u003e 2 x 1.253kg \u003cstrong\u003eArmature Weight:\u003c\/strong\u003e 2 x 0.597kg\u003c\/p\u003e\n\u003cp\u003eThis monitored double mini magnetic lock allows you to confirm its status (locked or unlocked) at a glance. Internally, it features voltage-free Hall Effect contacts with both Normally Open (N\/O) and Normally Closed (N\/C) options. These contacts can be connected to various devices, such as sounders, buzzers, alarm systems, or lights, triggering them when the magnet is activated\u003c\/p\u003e\n\u003cp\u003eThe 600-D-LED model also includes a dual red\/green LED for clear visual indication of its secure or released status. It is suitable for internal use and can be surface- or side-mounted on uPVC, timber, or metal doors.\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Input:\u003c\/strong\u003e Selectable 12V\/24V DC via internal jumper links\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHolding Force:\u003c\/strong\u003e 2 x 272kg (2 x 600lbs)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Draw:\u003c\/strong\u003e 1000mA @ 12V DC \/ 500mA @ 24V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMagnet Dimensions:\u003c\/strong\u003e 500mm (L) x 42mm (W) x 26mm (D)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArmature Plate Dimensions:\u003c\/strong\u003e 180mm (L) x 38mm (W) x 12mm (D) each\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003eFrequently Asked Questions (FAQs)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is the magnet running warm or hot?\u003c\/strong\u003e \"Power to Lock\" devices like magnetic locks require constant power and can naturally run warm. However, excessive heat is often caused by:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Mismatch:\u003c\/strong\u003e Using a 24V DC power supply for a magnet set to 12V DC operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsufficient Amperage:\u003c\/strong\u003e The power supply is not providing enough current, causing electrical resistance and heat.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Drop:\u003c\/strong\u003e A long cable run with an inadequate wire gauge can prevent sufficient current from reaching the magnet.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is the armature plate vibrating?\u003c\/strong\u003e This is typically due to a faulty or underrated power supply, or a voltage mismatch where a 12V DC power supply is used for a magnet set to 24V DC.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy won't the magnet lock properly?\u003c\/strong\u003e The most common reasons are:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eMisalignment:\u003c\/strong\u003e The armature plate is not correctly aligned with the magnetic lock.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Issues:\u003c\/strong\u003e The power supply is faulty, underrated, or there is a voltage mismatch (e.g., 12V DC supply for a 24V DC magnet).\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Tips\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerify Voltage Settings:\u003c\/strong\u003e Before powering on, always double-check that the wiring connections match your selected 12V DC or 24V DC power supply. Failure to do so can cause the lock to overheat or fail, potentially damaging the system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRegular Maintenance:\u003c\/strong\u003e Periodically clean the surfaces of both the magnet and the armature plate with a light oil to ensure optimal performance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003eBrackets (Optional)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePlease consider if you need fixing brackets for your installation.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e'L' Bracket:\u003c\/strong\u003e Typically required for outward-opening doors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e'ZL' Bracket:\u003c\/strong\u003e Typically required for inward-opening doors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e'L' Bracket Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.300kg x 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSize:\u003c\/strong\u003e 250mm (L) x 4mm (D) x (38mm x 38mm H)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdjustment:\u003c\/strong\u003e 8 screws allow alignment from -6mm to +19mm.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e'ZL' Bracket Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.550kg x 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSize:\u003c\/strong\u003e 180mm (L) x 4mm (D) x 2 x (46mm H x 46mm H)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdjustment:\u003c\/strong\u003e 4 screws allow alignment from -9mm to +31mm.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003eWhat's Included\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Double Magnetic Lock\u003c\/li\u003e\n\u003cli\u003e2 x Armature Plates\u003c\/li\u003e\n\u003cli\u003e1 x Fixing Kit\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Door Entry Online","offers":[{"title":"Default Title","offer_id":56327222264072,"sku":"U10005","price":55.4,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1034\/8294\/9896\/files\/magnetic-lock-u10005-600-d-led.jpg?v=1791731307"},{"product_id":"mini-magnetic-lock-600-s-led-u10002","title":"Magnetic Lock 600-S-LED","description":"\u003ch2\u003e600-S-LED Slimline Mini Magnetic Lock (12\/24V DC)\u003c\/h2\u003e\n\u003cp\u003eThis surface-mount slimline mini magnetic lock combines robust security with advanced monitoring features, making it an ideal choice for internal uPVC, timber, or metal doors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStrong Holding Force:\u003c\/strong\u003e Provides a secure holding force of 272kg (600lbs).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Voltage:\u003c\/strong\u003e Selectable 12V or 24V DC operation via internal jumper links.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLED Status Indicator:\u003c\/strong\u003e A dual red\/green LED offers a clear visual indication of the lock's status (locked or unlocked).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLock Monitoring:\u003c\/strong\u003e Features Hall Effect contacts (N\/O \u0026amp; N\/C) to monitor whether the magnet is locked or unlocked. This voltage-free output can be integrated with alarm systems, sounders, or lights to confirm the lock's status.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoor Status Monitoring:\u003c\/strong\u003e Includes a door status sensor to determine if the door is open or closed, even without power to the magnet. This allows for comprehensive access control monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Input:\u003c\/strong\u003e 12V \/ 24V DC (selectable)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Draw:\u003c\/strong\u003e 500mA @ 12V DC | 250mA @ 24V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHolding Force:\u003c\/strong\u003e 272kg (600lbs)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMagnet Dimensions:\u003c\/strong\u003e 250mm (L) x 42mm (W) x 26mm (D)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArmature Plate Dimensions:\u003c\/strong\u003e 180mm (L) x 38mm (W) x 12mm (D)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMagnet Weight:\u003c\/strong\u003e 1.253kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArmature Weight:\u003c\/strong\u003e 0.597kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation Brackets (Sold Separately):\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMounting brackets are often required for proper installation. Please select the appropriate bracket for your door type:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e'L' Bracket (for outward-opening doors):\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWeight: 0.300kg\u003c\/li\u003e\n\u003cli\u003eDimensions: 250mm (L) x 4mm (D) x 38mm x 38mm (H)\u003c\/li\u003e\n\u003cli\u003eProvides flexible alignment options.\u003cbr\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e'ZL' Bracket (for inward-opening doors):\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWeight: 0.550kg\u003c\/li\u003e\n\u003cli\u003eDimensions: 180mm (L) x 4mm (D) x 46mm x 46mm (H)\u003c\/li\u003e\n\u003cli\u003eAllows for precise armature plate positioning.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFrequently Asked Questions (FAQs):\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is the magnet running warm\/hot\u003cbr\u003e\u003c\/strong\u003e\"Power to Lock\" devices like magnetic locks require constant power and will naturally run warm. However, excessive heat can be caused by a voltage mismatch (e.g., using a 24V DC power supply for a 12V DC setting), insufficient amperage from the power supply, or a significant current drop due to long cable runs with inadequate wire gauge.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is the armature plate vibrating?\u003c\/strong\u003e \u003cbr\u003eVibration is typically a sign of an under-rated or faulty power supply, or a voltage mismatch where the magnet is set to 24V DC but the power supply is 12V DC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhy isn't the magnet locking properly?\u003c\/strong\u003e \u003cbr\u003eThe most common causes are incorrect alignment between the armature plate and the magnet, a faulty\/under-rated power supply, or a voltage mismatch (e.g., a 24V DC setting with a 12V DC supply).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eImportant Technical Note:\u003c\/strong\u003e Before applying power, always double-check that the internal jumper link is set to match your power supply voltage (12V or 24V DC). Failure to do so can cause the lock to overheat, fail to engage correctly, and may eventually damage the unit or your system. For optimal performance, periodically clean the surfaces of the magnet and armature plate with a light oil.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat's Included:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Magnetic Lock\u003c\/li\u003e\n\u003cli\u003e1 x Armature Plate\u003c\/li\u003e\n\u003cli\u003e1 x Fixing Kit\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Door Entry Online","offers":[{"title":"Default Title","offer_id":56327222657288,"sku":"U10002","price":30.71,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1034\/8294\/9896\/files\/magnetic-lock-u10002-600-s-led.jpg?v=1791730699"},{"product_id":"mini-magnetic-lock-600-s-led-ds","title":"Magnetic Lock 600-S-LED-DS","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e600-S-LED-DS - Slimline Mini Magnetic Lock (12\/24V DC)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSecure your entryways with the 600-S-LED-DS, a slimline surface-mount magnetic lock designed for performance and reliability. Offering a robust holding force of 272kg (600lbs), this lock is ideal for internal uPVC, timber, or metal doors.\u003c\/p\u003e\n\u003cp\u003eThis model includes advanced monitoring features:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLock Status Monitoring:\u003c\/strong\u003e Integrated Hall Effect contacts (N\/O \u0026amp; N\/C) allow you to verify whether the magnet is locked or unlocked. This can be connected to alarms, sounders, or indicator lights.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoor Status Monitoring (DS):\u003c\/strong\u003e A separate set of contacts monitors the door's position (open or closed), even when the lock is unpowered.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLED Indicator:\u003c\/strong\u003e A dual-colour LED provides a clear visual confirmation of the lock's status.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMagnet:\u003c\/strong\u003e 1.253kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArmature:\u003c\/strong\u003e 0.597kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Input:\u003c\/strong\u003e 12V \/ 24V DC (selectable via internal jumper)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHolding Force:\u003c\/strong\u003e 272kg (600lbs)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Draw:\u003c\/strong\u003e 500mA @ 12V DC | 250mA @ 24V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMagnet Dimensions:\u003c\/strong\u003e 250mm (L) x 42mm (W) x 26mm (D)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArmature Plate Dimensions:\u003c\/strong\u003e 180mm (L) x 38mm (W) x 12mm (D)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation Guides:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eManual\u003c\/li\u003e\n\u003cli\u003eMagnet Layout\u003c\/li\u003e\n\u003cli\u003eMounting Plate Layout\u003c\/li\u003e\n\u003cli\u003ePull Door Installation\u003c\/li\u003e\n\u003cli\u003ePush Door Installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eFAQs \u0026amp; Troubleshooting\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: The magnet feels very warm, almost hot. Is this normal?\u003c\/strong\u003e \u003cbr\u003e\"Power to Lock\" devices like magnetic locks will naturally run warm due to the constant power required. However, excessive heat is often caused by:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Mismatch:\u003c\/strong\u003e Using a 24V DC power supply for a magnet set to 12V DC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsufficient Amperage:\u003c\/strong\u003e The power supply cannot provide enough current, causing electrical resistance and heat.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Drop:\u003c\/strong\u003e Using an inadequate wire gauge over a long cable run, which prevents sufficient current from reaching the magnet.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cstrong\u003eQ: The armature plate is vibrating\u003cbr\u003e\u003c\/strong\u003eThis is typically caused by an under-rated or faulty power supply, or by powering a 24V DC-configured magnet with a 12V DC supply.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: The magnet isn't locking properly, and the door can be pulled open\u003c\/strong\u003e \u003cbr\u003eThe most common causes are:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eMisalignment:\u003c\/strong\u003e The armature plate is not correctly aligned with the magnet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Issues:\u003c\/strong\u003e The power supply is faulty, under-rated, or there is a voltage mismatch (e.g., 12V DC supply for a 24V DC setting).\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Tips \u0026amp; Brackets\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e Always verify that the jumper links are correctly set for your chosen power supply (12V DC or 24V DC) \u003cem\u003ebefore\u003c\/em\u003e turning on the power. Failure to do so can cause the lock to overheat, fail to engage, and eventually damage the system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaintenance:\u003c\/strong\u003e Periodically clean the magnet and armature plate surfaces with a light oil to ensure optimal performance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMounting Brackets (Sold Separately):\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e'L' Bracket (for outward-opening doors):\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eWeight: 0.300kg\u003c\/li\u003e\n\u003cli\u003eDimensions: 250mm (L) x 4mm (D) x 38mm (H)\u003c\/li\u003e\n\u003cli\u003eAdjustment: Allows the magnet to be aligned from -6mm to +19mm.\u003cbr\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e'ZL' Bracket (for inward-opening doors):\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eWeight: 0.550kg\u003c\/li\u003e\n\u003cli\u003eDimensions: 180mm (L) x 4mm (D) x 46mm (H)\u003c\/li\u003e\n\u003cli\u003eAdjustment: Allows the magnet to be aligned from -9mm to +31mm.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eWhat's Included\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Magnetic Lock\u003c\/li\u003e\n\u003cli\u003e1 x Armature Plate\u003c\/li\u003e\n\u003cli\u003e1 x Fixing Kit\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Door Entry Online","offers":[{"title":"Default Title","offer_id":56327222853896,"sku":null,"price":42.97,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1034\/8294\/9896\/files\/magnetic-lock-u10002ds-600-s-led-door-status.jpg?v=1791730864"},{"product_id":"mini-magnetic-lock-600-s-ds","title":"Magnetic Lock 600-S-DS","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e600-S-DS Mini Magnetic Lock: Slimline, Surface Mount, 12\/24V DC\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 600-S-DS is a slimline, surface-mounted magnetic lock designed for secure, internal door applications. Its key feature is \u003cstrong\u003eDoor Status (DS) monitoring\u003c\/strong\u003e, which uses voltage-free contacts within the magnet to signal whether the door is open or closed, even without power. These Normally Closed (N\/C) contacts can be wired to a sounder, buzzer, alarm system, or light to confirm the door's status when the magnet and armature plate are separated.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHolding Force:\u003c\/strong\u003e 272kg (600lbs)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuitability:\u003c\/strong\u003e Ideal for internal use on uPVC, timber, or metal doors (surface or side mount).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e Magnet: 1.253kg | Armature: 0.597kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Input:\u003c\/strong\u003e 12V \/ 24V DC (selectable via internal jumper links)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Draw:\u003c\/strong\u003e 500mA @ 12V DC | 250mA @ 24V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMagnet Dimensions:\u003c\/strong\u003e 250mm (L) x 42mm (W) x 26mm (D)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArmature Plate Dimensions:\u003c\/strong\u003e 180mm (L) x 38mm (W) x 12mm (D)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation \u0026amp; Technical Information\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation Guides:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eManual\u003c\/li\u003e\n\u003cli\u003eMagnet Layout\u003c\/li\u003e\n\u003cli\u003eMounting Plate Layout\u003c\/li\u003e\n\u003cli\u003ePull Door Installation\u003c\/li\u003e\n\u003cli\u003ePush Door Installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTech Tips \u0026amp; FAQs:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe magnet is running warm, almost hot\u003c\/strong\u003e \u003cbr\u003e\"Power-to-lock\" devices like magnetic locks require constant power and can naturally run warm. However, excessive heat is usually caused by:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Mismatch:\u003c\/strong\u003e Using a 24V DC power supply for a magnet set to 12V DC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsufficient Amperage:\u003c\/strong\u003e The power supply cannot provide enough current.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Drop:\u003c\/strong\u003e Using an inadequate wire gauge over a long cable run, causing insufficient current to reach the magnet.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cstrong\u003eThe armature plate is vibrating\u003cbr\u003e\u003c\/strong\u003eThis is typically caused by an under-rated or faulty power supply, or by powering a 24V DC magnet with a 12V DC supply.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe magnet does not lock, or the door opens easily\u003cbr\u003e\u003c\/strong\u003eThe most common cause is poor alignment between the armature plate and the magnet. It can also result from a faulty\/under-rated power supply or a voltage mismatch (e.g., a 24V DC magnet on a 12V DC supply).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e This magnetic lock operates on either 12V DC or 24V DC. Always verify the wiring connections and jumper settings are correct for your chosen power supply \u003cstrong\u003ebefore\u003c\/strong\u003e turning on the power. Failure to do so can cause the lock to overheat, fail to secure properly, and eventually damage the system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaintenance:\u003c\/strong\u003e Periodically clean the surfaces of both the magnet and the armature plate with a light oil to ensure optimal performance.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eBrackets (Sold Separately)\u003c\/h3\u003e\n\u003cp\u003ePlease consider if you require fixing brackets for your installation.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e'L' Bracket (for outward-opening doors):\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation:\u003c\/strong\u003e L Bracket Guide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.300kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 250mm (L) x (38mm x 38mm) (H) x 4mm (D)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdjustment:\u003c\/strong\u003e Allows the magnet to be aligned from -6mm (forward) to +19mm (backward).\u003cbr\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e'ZL' Bracket (for inward-opening doors):\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation:\u003c\/strong\u003e ZL Bracket Guide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.550kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 180mm (L) x (46mm x 46mm) (H) x 4mm (D)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdjustment:\u003c\/strong\u003e Allows the magnet to be aligned from -9mm (forward) to +31mm (backward).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eWhat's Included\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Magnetic Lock\u003c\/li\u003e\n\u003cli\u003e1 x Armature Plate\u003c\/li\u003e\n\u003cli\u003e1 x Fixing Kit\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Door Entry Online","offers":[{"title":"Default Title","offer_id":56327223214344,"sku":null,"price":39.77,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1034\/8294\/9896\/files\/magnetic-lock-u10001ds-600-s-door-status.jpg?v=1791730808"},{"product_id":"mini-magnetic-lock-600-s","title":"Magnetic Lock 600-S","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff0000;\"\u003eProud suppliers of the Crystal Maze 2017, 2018 \u0026amp; USA 2019 for our Drawer \u0026amp; Mini magnets\u003c\/span\u003e \u003cbr\u003e12\/24v dc surface mount slimline mini magnetic lock 600-S \u003cbr\u003e\u003cstrong\u003eHolding force:\u003c\/strong\u003e 272kg \u003cbr\u003e\u003cstrong\u003eMagnet weight:\u003c\/strong\u003e 1.253kg \u003cbr\u003e\u003cstrong\u003eArmature weight:\u003c\/strong\u003e 0.597kg \u003cbr\u003e\u003cstrong\u003eSuitable for:\u003c\/strong\u003e Internal use. Surface or side mount fitting on uPVC, timber or metal doors\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003ePower input:\u003c\/strong\u003e 12v\/24v dc selectable via internal jumper links \u003cbr\u003e\u003cstrong\u003eHolding force:\u003c\/strong\u003e 272kg (600lbs) \u003cbr\u003e\u003cstrong\u003eCurrent draw:\u003c\/strong\u003e 500ma @ 12v dc - 250ma @ 24v dc \u003cbr\u003e\u003cstrong\u003eMagnet size:\u003c\/strong\u003e 250l x 42w x 26d mm \u003cbr\u003e\u003cstrong\u003eArmature plate size:\u003c\/strong\u003e 180 x 38w x 12d mm\u003c\/p\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eThe magnet is running very warm, almost hot\u003c\/strong\u003e \u003cbr\u003e'Power to Lock' devices such as magnetic locks can run warm as they require constant power to them, however, the most common causes of this are the magnet is 12v dc operation, but the power supply is 24v dc Electrical resistance in the circuitry will create heat but if the power supply is providing insufficient amperage then the magnet will feel hot Also, if there is a current drop because of a long cable run with an inadequate wire gauge, the magnet will not get sufficient current and will run hot\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe armature plate is vibrating\u003c\/strong\u003e \u003cbr\u003eThis is due to either a faulty or under rated power supply, or the magnet is 24v dc operation and the power supply is 12v dc\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe magnet does not lock, the door can be pulled open quite easily\u003c\/strong\u003e \u003cbr\u003eThe most common cause is incorrect alignment of the armature plate to the magnetic lock, a faulty or under rated power supply, or the magnet is 24v dc operation and the power supply is 12v dc \u003ca href=\"\/acatalog\/Armature_plate_fitting.pdf\" target=\"_blank\"\u003e\u003cimg border=\"0\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTech Tips\u003c\/strong\u003e This magnetic lock will operate via 12v dc or 24v dc, however, please ensure you check the wiring connections correctly for use with a 12v dc power supply or 24v power supply before you turn the power on If you fail to check this, then you run the risk of either the magnetic lock running very hot or it not locking correctly Eventually you will cause damage to the system you have installed Periodically clean the surface of both the magnet and armature plate with light oil  Please consider if you require any fixing brackets. Typically an 'L' bracket is required for outward opening doors. A 'ZL' bracket is required for inward opening doors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eL bracket weight:\u003c\/strong\u003e 0.300kg \u003cbr\u003e\u003cstrong\u003eL bracket size:\u003c\/strong\u003e 250l x 4d x (38 x 38h) mm \u003cbr\u003e\u003cstrong\u003eL bracket adjustment:\u003c\/strong\u003e 8 screw adjustment (4 each side) allowing the magnet to be aligned from -6mm forward to 19mm backward \u003cbr\u003e\u003cstrong\u003eZL bracket weight:\u003c\/strong\u003e 0.550kg \u003cbr\u003e\u003cstrong\u003eZL bracket size:\u003c\/strong\u003e 180l x 4d x 2 x (46h x 46h) mm \u003cbr\u003e\u003cstrong\u003eZL bracket adjustment:\u003c\/strong\u003e 4 screw adjustment (2 each side) allowing the magnet to be aligned from -9mm forward to 31mm backward\u003c\/p\u003e\n\u003ch3\u003eSupplied With\u003c\/h3\u003e\n\u003cp\u003e1 x Magnetic lock 1 x Armature plate 1 x Fixing kit\u003c\/p\u003e","brand":"Door Entry Online","offers":[{"title":"Default Title","offer_id":56327223443720,"sku":"600-S","price":25.38,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1034\/8294\/9896\/files\/magnetic-lock-u10001-600-s_b017412e-9f9c-46b9-a1d1-fda6a0f10245.jpg?v=1791730567"},{"product_id":"magnetic-lock-600-m-u1000","title":"Magnetic Lock 600-M","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe 600-M is a 12\/24V DC mini mortice magnetic lock, perfect for securing uPVC, timber, or metal doors. With a holding force of 272kg, this compact and powerful lock is suitable for both internal and external applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e For external use, the lock's wiring must be fully concealed.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Input:\u003c\/strong\u003e 12\/24V DC (selectable via wiring)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHolding Force:\u003c\/strong\u003e 272kg (600lbs)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Draw:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e500mA @ 12V DC\u003c\/li\u003e\n\u003cli\u003e250mA @ 24V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMagnet Dimensions:\u003c\/strong\u003e 229mm (L) x 38mm (W) x 27mm (D)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArmature Plate Dimensions:\u003c\/strong\u003e 180mm (L) x 38mm (W) x 12mm (D)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMagnet Weight:\u003c\/strong\u003e 1.253kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArmature Weight:\u003c\/strong\u003e 0.597kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation \u0026amp; Technical Information\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWiring:\u003c\/strong\u003e This magnetic lock can be operated at either 12V DC or 24V DC. Before powering on, ensure the wiring connections are correct for your chosen voltage to prevent overheating, locking failure, or system damage.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaintenance:\u003c\/strong\u003e Periodically clean the surfaces of both the magnet and the armature plate with a light oil to ensure optimal performance.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQs)\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhy does the magnet feel very warm or hot?\u003c\/strong\u003e \"Power to Lock\" devices like magnetic locks require constant power and can naturally run warm. However, excessive heat is often caused by:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Mismatch:\u003c\/strong\u003e A 12V DC magnet connected to a 24V DC power supply.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsufficient Amperage:\u003c\/strong\u003e The power supply is not providing enough current.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Drop:\u003c\/strong\u003e A long cable run with an inadequate wire gauge is causing a loss of current.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is the armature plate vibrating?\u003c\/strong\u003e Vibration is typically due to an under-rated or faulty power supply, or a voltage mismatch (e.g., a 24V DC magnet connected to a 12V DC power supply).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy won't the magnet lock properly?\u003c\/strong\u003e The most common reasons for a weak lock are:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIncorrect Alignment:\u003c\/strong\u003e The armature plate is not correctly aligned with the magnet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Issues:\u003c\/strong\u003e The power supply is faulty, under-rated, or there is a voltage mismatch.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eWhat's Included\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Magnetic Lock\u003c\/li\u003e\n\u003cli\u003e1 x Armature Plate\u003c\/li\u003e\n\u003cli\u003e1 x Fixing Kit\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Door Entry Online","offers":[{"title":"Default Title","offer_id":56327223771400,"sku":"U1000","price":38.71,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1034\/8294\/9896\/files\/mortice-magnetic-lock-u10000-600-m.jpg?v=1791731106"},{"product_id":"mortice-magnetic-lock-600-m-monitored-u1000r","title":"Magnetic Lock 600-M - Monitored","description":"\u003ch2\u003e12\/24V DC Mini Mortice Magnetic Lock (Monitored) | 600-M\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e 600-M (Monitored)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHolding Force:\u003c\/strong\u003e 272kg (600lbs)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Voltage:\u003c\/strong\u003e 12\/24V DC (selectable)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuitability:\u003c\/strong\u003e Mortice fitting for internal and external use on uPVC, timber, or metal doors. (\u003cem\u003eNote: For external use, the magnetic lock wiring must be fully concealed.\u003c\/em\u003e)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMagnet Weight:\u003c\/strong\u003e 1.253kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArmature Weight:\u003c\/strong\u003e 0.597kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe \"monitored\" feature means the lock's status can be tracked to confirm whether it is locked or unlocked. This is achieved via a set of voltage-free Hall Effect contacts inside the magnet, providing Normally Open (N\/O) and Normally Closed (N\/C) options. These contacts can be connected to devices like sounders, buzzers, or alarm systems, triggering an action when the magnet and armature plate are separated.\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Input:\u003c\/strong\u003e 12V\/24V DC (selectable via wiring connection)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Draw:\u003c\/strong\u003e 500mA @ 12V DC | 250mA @ 24V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMagnet Dimensions:\u003c\/strong\u003e 229mm (L) x 38mm (W) x 27mm (D)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArmature Plate Dimensions:\u003c\/strong\u003e 180mm (L) x 38mm (W) x 12mm (D)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003eCommon FAQs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: The magnet feels very warm, almost hot. Is this normal?\u003c\/strong\u003e A: \"Power to lock\" devices like magnetic locks can run warm due to the constant power they require. However, excessive heat is often caused by:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Mismatch:\u003c\/strong\u003e Using a 24V DC power supply for a magnet set to 12V DC operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsufficient Amperage:\u003c\/strong\u003e The power supply is not providing enough current.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Drop:\u003c\/strong\u003e A long cable run with an inadequate wire gauge can prevent sufficient current from reaching the magnet.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cstrong\u003eQ: The armature plate is vibrating. What's causing this?\u003c\/strong\u003e A: This is typically due to a faulty or underrated power supply, or a voltage mismatch where a 12V DC power supply is used for a magnet set to 24V DC operation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: The magnet isn't locking, and the door can be pulled open easily.\u003c\/strong\u003e A: The most common causes are:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eIncorrect Alignment:\u003c\/strong\u003e The armature plate is not properly aligned with the magnetic lock.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Issues:\u003c\/strong\u003e The power supply is faulty, underrated, or there is a voltage mismatch (e.g., 12V DC supply for a 24V DC lock setting).\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical \u0026amp; Installation Tips\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Selection:\u003c\/strong\u003e This lock operates on either 12V DC or 24V DC. Before powering on, double-check that the wiring connections match your power supply's voltage. Failure to do so can result in the lock overheating, failing to secure properly, and eventually causing damage to the system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaintenance:\u003c\/strong\u003e Periodically clean the surfaces of both the magnet and the armature plate with a light oil to ensure optimal performance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003eWhat's Included\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Magnetic Lock\u003c\/li\u003e\n\u003cli\u003e1 x Armature Plate\u003c\/li\u003e\n\u003cli\u003e1 x Fixing Kit\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Door Entry Online","offers":[{"title":"Default Title","offer_id":56327224000776,"sku":"U1000R","price":39.91,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1034\/8294\/9896\/files\/monitored-mortice-magnetic-lock-u10000r-600-m-monitored.jpg?v=1791731165"}],"url":"https:\/\/www.doorentryonline.co.uk\/collections\/magnetic-locks-maglocks-magnetic-lock-brackets.oembed","provider":"Door Entry Online","version":"1.0","type":"link"}